AC2 4E1 PDF

Buy used ESCO ACE1 with warranty at or ask for a quote. Proven Quality at the best price. Class II Biological Safety Cabinet ACE1 Esco. Price: Contact Request for quotation. Unit: Pce. Delivery time: Contact. Gross weight: 0 kg. Place of delivery . Class II. Biological Safety Cabinet. Esco Airstream Class (AC2 – E/S/D/G/N) II BSC User and Service Manual. Version F – Released July

Author: Tulkree Jujin
Country: Burkina Faso
Language: English (Spanish)
Genre: Music
Published (Last): 27 July 2010
Pages: 216
PDF File Size: 14.93 Mb
ePub File Size: 8.25 Mb
ISBN: 112-8-95923-626-8
Downloads: 43271
Price: Free* [*Free Regsitration Required]
Uploader: Metaur

Work tray s is are aesthetically designed with upward-curving back edge which makes cleaning the surface a breeze with no hard-to-clean joints. In addition, a small portion of the filtered downflow air enters the airflow intake perforations referred to as side capture zones at the front of the side walls at high velocities indicated on the diagram with small blue arrows.

ESCO Airstream Microbiological Safety Cabinets Class II

Each work surface tray is fabricated from a single piece a2c stainless steel without any fasteners, thus eliminating difficult-to-clean joints; each set of trays has lifting provisions to facilitate easy access to the lower drain spillage trough. Interior surfaces are designed to eliminate protrusions, channels, and any other dif.

Increases exterior dimensions Cabinet Accessories IV Bar with Hooks For pharmacy applications, a built-in intravenous bar provides a convenient means to hang and store intravenous bags during work. Main Features Designed for ergonomics: No factory-fitting is necessary. With the inflow, air is moved within the cabinet, through an air return path underneath the work surface, and behind the ad2 wall to a plenum in which the blower system is mounted.

The cabinet must be removed from a Telescoping Support Stand prior to adjustments. The filter assembly is constructed in accordance with EN requirements. Heat Output in British Thermal Units. The backward curved wheel with external rotor motor delivers classleading energy efficiency for lower operating costs. Stainless steel IV bar with 6 hooks. Please refer to the text of the a2 for the exact scope of delivery. 44e1

  EVERMOTION ARCHMODELS VOL 113 PDF

ESCO Airstream Microbiological Safety Cabinets Class II

A combination of inflow and downflow air streams forms an air barrier that wc2 contaminated room air from entering the work zone, and prevents work surface emissions from escaping the work zone. Apart from convenience, the IV acc2 increases the effective cabinet working zone. Standard with caster wheels Motorized electrically-adjustable White oven-baked epoxy powder-coated finish Maximum weight supported: Actual sash opening is larger than tested opening, and improves reach into the work zone without compromising safety.

The type-testing performed included stringent evaluations of cabinet airflows, containment, and operator comfort factors. E-series Features UV-absorbing tempered glass sides increase operator comfort and provide a high level of protection against harmful UV rays when 4r1 UV lamp is installed; glass is also stronger and more durable compared to plastic materials. Airstream AC2 Series cabinets are warranted for 3 years excluding consumable parts and accessories.

PVC Armrest Chemically treated, improves operator comfort, easy to clean. The industry-exclusive features designed into this cabinet include a world first patent pending backward curve motorized impeller acc2 conventional blowers positive plenum design.

The cabinet work zone has no welded joints to collect contaminants or rust. Programmable automatic UV light timer simplifies operation while extending UV lamp life and saving energy. These models are suitable for use with agents assigned to biosafety levels 1, 2 and 3 in particular 2 and 3 and provide unparalleled protection for the operator and the environment from biological hazards, in addition to an unequalled level of protection for the product from external airborne contamination and cross 4e.

Built-in warm white, electronically ballasted, k lighting provides excellent illumination of the work zone and reduces operator fatigue. Av2 airflow visualization has been employed during type-testing in our laboratories to ensure maximum containment for improved operator protection, and better airflow uniformity within the work zone for better product protection.

The uniform nature of the air stream ensures ac high level of protection against cross-contamination between various samples placed at different locations within the cabinet work zone.

  CONFIGURATION ROUTAGE STATIQUE CISCO PDF

They do not represent the scope of delivery. Factory installed; specify when ordering.

Standard work surface is a multi-piece work tray. The following illustrations and descriptions refer to the instrument model and are drawn from brochures. A small portion of the ULPA filtered downflow enters the intake perforations at the side capture zones at a higher velocity small purple arrows. Cleanliness Within Working Area.

The cabinet must be removed from a Telescoping Support Stand prior to adjustments. Downflow and Exhaust Filter Type.

UV lamp is not a substitute for good cleaning practices, and its effective lifespan is limited to approx. Standards Compliance 4s1 E-series with transparent glass side walls and S-series with stainless steel interior.

Drawing from a dialogue of over 20 years with our users, Esco engineers have re-designed every component for better performance, longer durability and easier use.

ESCO Airstream Microbiological Safety Cabinets Class II

Increases exterior dimensions Cabinet Accessories Anti Blowback Valve IV Bar with Hooks For pharmacy applications, a built-in intravenous bar provides a convenient means to hang and store intravenous bags during work. Inflow air travels through a return path toward the common air plenum fan plenum at the top of the cabinet. Durable grade stainless steel work surface will never rust, chip, or generate particles. This forms an air barrier that ensures no contaminated air enters the actual work zone, and also prevents any contamination from escaping the cabinet.

Optimized air curtain maintains personnel and product protection even in the unlikely event of inflow and downflow imbalance that would compromise protection on a conventional cabinet.

Another key innovation for which Esco is now recognised for – our use of mini-pleat ULPA Ultra Low Penetration Air filter technology as opposed to conventional HEPA filters – is especially pertinent to the applications for which these cabinets have been designed for.

External Dimensions L x W x H x x mm